070-0104-00

Circuit Breakers

CIRCUIT BREAKER

070-0104-00

5925-00-868-4335

5925 - Circuit Breakers

Cts Fabri-Tek Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.700 minimum at 200 pct and 1.500 maximum at 200 pct single location

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Switch Terminal Type

    turret

  • Switch Voltage Rating And Type In Volts

    130.0 ac and 28.0 dc

  • Unpackaged Unit Weight

    2.000 ounces

  • Thread Series Designator

    uns

  • Terminal Type And Quantity

    2 tab w/screw

  • Maximum Continuous Load Current Rating Per Pole

    7.5 amperes ac single location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Nominal Thread Size

    0.468 inches

  • Body Style

    2a single pole type

  • Case Material

    plastic

  • Bushing Length

    0.250 inches nominal

  • Body Length

    1.781 inches nominal

  • Body Width

    0.656 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.341 inches nominal

  • Switch Contact Arrangement

    single pole, double throw

  • Pole Quantity

    1

  • Arc Quenching Method

    magnetic blowout

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Mounting Surface To Terminal End Distance

    1.669 inches nominal

  • Mounting Facility Type And Quantity

    thd bushing

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    magnetic single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Auxiliary Switch Function And Quantity

    1 control

  • Internal Trip Release Configuration

    series trip single location

  • Switch Location And Position Designation

    external at pole one

  • Switch Current Rating And Type In Amps

    7.0 ac and 7.0 dc

  • Frequency In Hertz

    60.0

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...