48-301SH
Circuit Breakers
CIRCUIT BREAKER
48-301SH
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Thread Quantity Per Inch27 
- 
                                    Body Stylemultipole-single actuator type 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps6.0 ac all locations 
- 
                                    Bushing Length0.300 inches nominal 
- 
                                    Center To Center Distance Between Terminals Parallel To Length1.560 inches nominal 
- 
                                    Frequency In Hertz60.0 all locations 
- 
                                    Body Width3.150 inches nominal 
- 
                                    Unpackaged Unit Weight0.312 pounds 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Terminal Type And Quantity6 screw 
- 
                                    Inclosure Protection Type For Which Designedgeneral purpose 
- 
                                    Body Height2.490 inches nominal 
- 
                                    Center To Center Distance Between Terminals Parallel To Width2.320 inches nominal 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts500.0 ac all locations 
- 
                                    Thread Series Designatoruns 
- 
                                    Case Materialplastic 
- 
                                    Trip Release Methodthermal all locations 
- 
                                    Trip Release Ambient Temp Rating70.0 deg fahrenheit nominal all locations 
- 
                                    Maximum Continuous Load Current Rating Per Pole1.0 amperes ac all locations 
- 
                                    Fragility Factormoderately rugged 
- 
                                    Pole Quantity3 
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Actuator Position Designationat pole two 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 all locations 
- 
                                    Mounting Facility Type And Quantity1 threaded bushing 
- 
                                    Nominal Thread Size0.375 inches 
- 
                                    Manual Actuator Type And Quantity1 push button 
- 
                                    Internal Trip Release Configurationseries trip all locations 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Trip Release Characteristictime delay all locations 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Body Length1.810 inches nominal 
- 
                                    Reset Methodmanual 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current10.000 minimum at 200 pct all locations and 45.000 maximum at 200 pct all locations 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    