Circuit Breakers
CIRCUIT BREAKER
PS2-3904-5
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Body Style12a single pole type 
- 
                                    Body Length3.750 inches nominal 
- 
                                    Boss Height0.156 inches nominal 
- 
                                    Mounting Surface To Terminal End Distance3.184 inches nominal 
- 
                                    Pole Quantity1 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Maximum Continuous Load Current Rating Per Pole25.0 amperes dc single location 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps5000.0 dc single location 
- 
                                    Trip Release Methodmagnetic-hydraulic single location 
- 
                                    Ultimate Trip Time Per Pole In Seconds0.180 minimum and 2.000 maximum single location 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Internal Trip Release Configurationseries trip single location 
- 
                                    Nominal Thread Size0.138 inches 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current0.120 minimum at 200 pct and 0.160 maximum at 200 pct and 0.080 minimum at 400 pct and 0.140 maximum at 400 pct single location 
- 
                                    Design Control Referenceps2-3904-5 
- 
                                    Manufacturers Code23917 
- 
                                    Thread Series Designatorunc 
- 
                                    Reference Number Differentiating Characteristicsselected and tested for polaris weapon system 
- 
                                    Body Width0.984 inches nominal 
- 
                                    Case Materialplastic 
- 
                                    Center To Center Distance Between Terminals Parallel To Length3.062 inches nominal 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length2.750 inches nominal 
- 
                                    Mounting Facility Type And Quantity2 threaded hole 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts32.0 dc single location 
- 
                                    Circuit Protection Typeovercurrent single location 
- 
                                    Trip Release Characteristictime delay single location 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 single location 
- 
                                    Reset Methodmanual 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Actuator Functionreset 
- 
                                    Actuator Position Designationat pole one 
- 
                                    Terminal Type And Quantity2 threaded stud 