RY4PA3B3L03
Relays and Solenoids
RELAY,ELECTROMAGNETIC
RY4PA3B3L03
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Main Contact Load Current Rating At Maximum Rated Voltage
5.0 amperes ac resistive load and 5.0 amperes dc resistive load
-
Operating Voltage Rating And Type At Specified Temp
115.0 volts ac 25 deg celsius single winding
-
Environmental Protection
hermetic
-
Mounting Facility Type And Quantity
4 threaded stud single mounting facility
-
Arc Quenching Method
air
-
Thread Quantity Per Inch
32 single mounting facility
-
Winding Quantity
1
-
Thread Class
2a single mounting facility
-
Case Material
metal
-
Thread Direction
right-hand single mounting facility
-
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Overall Length
1.531 inches maximum
-
Overall Height
2.187 inches maximum
-
Nonpile-Up Main Contact Arrangement
4 pole, double throw, one position momentary
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.187 inches nominal single mounting facility
-
Purpose For Which Designed
general
-
Coil Quantity
1
-
Thread Series Designator
unc single mounting facility
-
Cubic Measure
3.783 cubic inches
-
Overall Width
1.130 inches maximum
-
Time Delay
0.05 seconds maximum fixed release time
-
Winding Dc Resistance Rating
1.4 kilohms nominal single winding
-
Center To Center Distance Between Mounting Facilities Parallel To Width
0.687 inches nominal single mounting facility
-
Duty Type
continuous
-
Time Delay
0.02 seconds maximum fixed operate time
-
Specification/Standard Data
81349-mil-r-5757/15 government specification
-
Terminal Type And Quantity
14 wire hook all functions
-
Test Data Document
81349-mil-r-5757 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
~1
data on certain environmental and performance
-
Frequency In Hertz
60.0 nominal
-
Storage Type
general purpose warehouse
-
Mounting Facility Pattern
rectangular single mounting facility
-
Main Contact Load Current Rating At Maximum Rated Voltage
800.0 milliamperes ac lamp load and 800.0 milliamperes dc lamp load
-
Nominal Thread Size
0.138 inches single mounting facility
-
Fragility Factor
moderately rugged
-
Main Contact Load Current Rating At Maximum Rated Voltage
3.0 amperes ac inductive load and 3.0 amperes dc inductive load
Related Parts by Category
Related Parts by Manufacturer
Certified toAS6081 Methods