7614618
Coils and Transformers
TRANSFORMER,POWER AUTOTRANSFORMER
7614618
TRANSFORMER,POWER AUTOTRANSFORMER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Terminal Type And Quantity
3 terminal block w/screws
 - 
                                    
Scale Direction And Range (Non-Core)
+0.0/+130.0 clockwise
 - 
                                    
Mounting Bolt Circle Diameter
1.750 inches nominal single mounting facility single center group
 - 
                                    
Overall Length
6.813 inches nominal
 - 
                                    
Inclosure Type
open
 - 
                                    
Winding Operating Voltage
115.00 ac pounds per hour wet single component single primary input
 - 
                                    
Winding Power Rating
860.0 volts-amperes single component single primary output
 - 
                                    
Thread Quantity Per Inch
32 single group
 - 
                                    
Mounting Method
threaded hole single group
 - 
                                    
Thread Class (Non-Core)
2b single group
 - 
                                    
Thread Direction (Non-Core)
right-hand single group
 - 
                                    
Thread Series Designator
unf single group
 - 
                                    
Winding Operating Voltage
0.00 ac pounds per hour dry single component single primary output and 135.00 ac pounds per hour with retaining chain single component single primary output
 - 
                                    
Frequency Rating
400.0 hertz minimum single component and 2.4 kilohertz maximum single component
 - 
                                    
Mounting Facility Quantity
3 single group
 - 
                                    
Reliability Indicator
not established
 - 
                                    
Input-Output Phase Relationship
single phase to single phase single component
 - 
                                    
Dummy Terminal Quantity (Non-Core)
2
 - 
                                    
Winding Operating Current
5.0 amperes nominal b and better drop siding single component single primary output
 - 
                                    
Winding Function And Quantity
1 primary, variable autotransformer type single component
 - 
                                    
Nominal Thread Size
0.190 inches single group
 - 
                                    
Body Outside Diameter
4.938 inches nominal
 - 
                                    
Body Length
5.063 inches nominal
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    