262413-10
Filters and Networks
FILTER,BAND PASS
262413-10
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Frequency Band Width Per Function
1.93375 kilohertz 3rd band pass and 1.97625 kilohertz 3rd band pass
-
Reference Frequency Per Function
1.955 single radio interference pulses per second
-
Frequency Band Width Per Function
1.93375 kilohertz 2nd band pass and 1.97625 kilohertz 2nd band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 3rd band pass
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd band pass
-
Source Impedance Rating Per Function
600.0 ohms 3rd band pass
-
Load Impedance Per Function
600.0 ohms 3rd band pass
-
Special Features
electrostatic shield brought out to terminal six
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 minimum 3rd band pass and 30.0 maximum 3rd band pass
-
Specified Frequencies Of Discrimination Per Function
1.93375 kilohertz 2nd band pass and 1.9125 kilohertz 2nd band pass and 1.97625 kilohertz 2nd band pass and 1.9975 kilohertz 2nd band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 2nd band pass
-
Frequency Band Width Per Function
1.93375 kilohertz 1st band pass and 1.97625 kilohertz 1st band pass
-
Functional Terminal Type And Quantity
1 turret ground 3rd function
-
Source Impedance Rating Per Function
600.0 ohms 2nd band pass
-
Load Impedance Per Function
600.0 ohms 2nd band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 minimum 1st band pass and 30.0 maximum 1st band pass
-
Functional Terminal Type And Quantity
3 turret output 2nd function
-
Overall Height
3.230 inches nominal
-
Body Width
1.410 inches maximum
-
Inclosure Type
hermetically sealed
-
Principal Circuitry Type Per Function
inductance-capacitance 1st band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 1st band pass
-
Source Impedance Rating Per Function
600.0 ohms 1st band pass
-
Load Impedance Per Function
600.0 ohms 1st band pass
-
Functional Terminal Type And Quantity
2 turret input 1st function
-
Mounting Facility Screw Thread Series Designator
unc
-
Features Provided
electrostatic shield
-
Mounting Facility Type And Quantity
2 threaded stud
-
Nominal Thread Size
0.138 inches
-
Specified Frequencies Of Discrimination Per Function
1.93375 kilohertz 1st band pass and 1.9125 kilohertz 1st band pass and 1.97625 kilohertz 1st band pass and 1.9975 kilohertz 1st band pass
-
Average Life Rating In Hours
10000.0
-
Body Length
3.000 inches nominal
-
Maximum Dielectric Withstanding Dc Voltage
500.0 volts at sea level
-
Vibration Resistance Range In Hertz
+10.0/+500.0
-
Reference Frequency Per Function
1.955 single radio interference two phase to two phase
-
Principal Circuitry Type Per Function
inductance-capacitance 3rd band pass
-
Operating Temp Range
-55.0/+65.0 deg celsius
-
Style Designator
rectangular terminal/terminals on one surface
-
Reference Frequency Per Function
1.955 single radio interference two phase to three phase
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 minimum 2nd band pass and 30.0 maximum 2nd band pass
-
Body Material
metal
-
Mounting Facility Type And Quantity
4 threaded hole
-
Body Height
2.950 inches nominal
-
Specified Frequencies Of Discrimination Per Function
1.97625 kilohertz 3rd band pass and 1.9125 kilohertz 3rd band pass and 1.93375 kilohertz 3rd band pass and 1.9975 kilohertz 3rd band pass
Related Parts by Category
Related Parts by Manufacturer


AS6081 Methods