0740637
Circuit Breakers
CIRCUIT BREAKER
0740637
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Fragility Factor
moderately rugged
 - 
                                    
Thread Series Designator
unc
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.812 inches nominal
 - 
                                    
Pole Quantity
1
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
575.0 dc single location
 - 
                                    
Internal Trip Release Configuration
series trip single location
 - 
                                    
Nominal Thread Size
0.138 inches
 - 
                                    
Trip Release Characteristic
time delay single location
 - 
                                    
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
 - 
                                    
Body Style
single pole type
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
 - 
                                    
Terminal Type And Quantity
2 tab w/screw
 - 
                                    
Overall Length
2.190 inches nominal
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
0.780 inches nominal
 - 
                                    
Inclosure Protection Type For Which Designed
shock resistant and salt spray proof and vibration resistant and fungus resistant
 - 
                                    
Reset Method
automatic
 - 
                                    
Case Material
plastic
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
28.0 dc single location
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
8.000 minimum at 200 pct single location and 50.000 maximum at 200 pct single location
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Body Width
0.750 inches nominal
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
15.0 amperes dc single location
 - 
                                    
Mounting Facility Type And Quantity
2 threaded hole
 - 
                                    
Mounting Surface To Terminal End Distance
1.430 inches maximum
 - 
                                    
Thread Quantity Per Inch
32
 - 
                                    
Circuit Protection Type
overcurrent single location
 - 
                                    
Trip Release Method
thermal single location
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    