Technical Characteristics

  • Thread Pitch Diameters

    +0.3503/+0.3537 inches

  • Bushing Length

    0.380 inches maximum

  • Case Material

    metal

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.605 inches maximum

  • Pole Quantity

    1

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    magnetic single location

  • Trip Release Characteristic

    time delay single location

  • Internal Trip Release Configuration

    series trip single location

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shock resistant and vibration resistant

  • Thread Series Designator

    unef

  • Terminal Type And Quantity

    2 wire hook

  • Body Style

    2a single pole type

  • Body Length

    1.562 inches maximum

  • Body Width

    0.625 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Special Handling Feature

    magnetic

  • Maximum Continuous Load Current Rating Per Pole

    1.25 amperes ac and 1.25 amperes dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac and 50.0 dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac and 1000.0 dc single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Nominal Thread Size

    0.375 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 200 pct and 9.000 maximum at 200 pct single location

  • Frequency In Hertz

    60.0 or 400.0

  • Unpackaged Unit Weight

    1.800 ounces

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...