AM12HEMG6-10-50VDC5
Circuit Breakers
CIRCUIT BREAKER
AM12HEMG6-10-50VDC5
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Mounting Surface To Terminal End Distance
2.461 inches minimum and 2.481 inches maximum
 - 
                                    
Pole Quantity
1
 - 
                                    
Mounting Facility Type And Quantity
2 threaded hole
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Thread Quantity Per Inch
32
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Internal Trip Release Configuration
series trip
 - 
                                    
Nominal Thread Size
0.138 inches
 - 
                                    
Inclosure Protection Type For Which Designed
explosion resistant and fungus resistant and moisture resistant
 - 
                                    
Switch Terminal Type
tab,solder lug
 - 
                                    
Switch Current Rating And Type In Amps
5.0 ac and 1.0 dc
 - 
                                    
Switch Voltage Rating And Type In Volts
125.0 ac and 50.0 dc
 - 
                                    
Test Data Document
12909-400675 drawing
 - 
                                    
Thread Series Designator
unc
 - 
                                    
Body Style
single pole type
 - 
                                    
Body Length
2.490 inches minimum and 2.510 inches maximum
 - 
                                    
Body Width
0.740 inches minimum and 0.760 inches maximum
 - 
                                    
Case Material
plastic
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.052 inches minimum and 2.072 inches maximum
 - 
                                    
Fragility Factor
moderately rugged
 - 
                                    
Boss Height
0.130 inches minimum and 0.150 inches maximum
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
1.928 inches minimum and 1.948 inches maximum
 - 
                                    
Switch Contact Arrangement
single pole,double throw
 - 
                                    
Arc Quenching Method
magnetic blowout
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
10.0 amperes dc
 - 
                                    
Circuit Protection Type
overcurrent
 - 
                                    
Trip Release Method
magnetic-hydraulic
 - 
                                    
Trip Release Characteristic
time delay
 - 
                                    
Reset Method
manual
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Actuator Position Designation
at pole one
 - 
                                    
Auxiliary Switch Function And Quantity
1 control
 - 
                                    
Switch Location And Position Designation
external at pole one
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
0.170 minimum at 200 pct and 0.550 maximum at 200 pct
 - 
                                    
Terminal Type And Quantity
2 threaded stud
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    