700-020-5

Circuit Breakers

CIRCUIT BREAKER

700-020-5

5925-00-960-5214

5925 - Circuit Breakers

Eaton Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic single location

  • Special Handling Feature

    magnetic

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    1 push button

  • Nominal Thread Size

    0.469 inches

  • Unpackaged Unit Weight

    0.093 pounds

  • Body Width

    0.750 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.693 inches minimum and 0.713 inches maximum

  • Terminal Type And Quantity

    2 tab w/screw

  • Frequency In Hertz

    60.0 single location

  • Body Style

    single pole type

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Trip Release Characteristic

    time delay single location

  • Inclosure Protection Type For Which Designed

    explosion proof

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location and 28.0 dc single location

  • Internal Trip Release Configuration

    series trip single location

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac single location and 5.0 amperes dc single location

  • Pole Quantity

    1

  • Trip Delay Time In Seconds Per Rated Continuous Current

    5.000 minimum at 200 pct single location and 55.000 maximum at 200 pct single location

  • Body Length

    1.094 inches maximum

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Arc Quenching Method

    air

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    6000.0 ac single location and 6000.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

  • Bushing Length

    0.240 inches minimum and 0.260 inches maximum

  • Mounting Surface To Terminal End Distance

    1.812 inches maximum

  • Case Material

    plastic

  • Thread Series Designator

    uns

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...