6752-14-5
Circuit Breakers
CIRCUIT BREAKER
6752-14-5
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Mounting Facility Type And Quantity2 threaded hole 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Circuit Protection Typeovercurrent single location 
- 
                                    Trip Release Methodthermal single location 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current12.000 minimum at 200 pct single location and 38.000 maximum at 200 pct single location 
- 
                                    Manual Actuator Type And Quantity1 push-pull 
- 
                                    Switch Voltage Rating And Type In Volts115.0 ac and 28.0 dc 
- 
                                    Switch Contact Arrangementsingle pole, double throw 
- 
                                    Pole Quantity1 
- 
                                    Maximum Continuous Load Current Rating Per Pole5.0 amperes ac single location and 5.0 amperes dc single location 
- 
                                    Body Length2.189 inches maximum 
- 
                                    Internal Trip Release Configurationseries trip single location 
- 
                                    Nominal Thread Size0.138 inches 
- 
                                    Switch Location And Position Designationexternal at pole one 
- 
                                    Inclosure Protection Type For Which Designedexplosion proof 
- 
                                    Center To Center Distance Between Terminals Parallel To Length1.190 inches nominal 
- 
                                    Trip Release Ambient Temp Rating25.0 deg celsius nominal single location 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Switch Current Rating And Type In Amps7.0 ac and 4.0 dc 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps4200.0 ac single location and 6000.0 dc single location 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent115.0 single location 
- 
                                    Frequency In Hertz400.0 single location 
- 
                                    Body Stylesingle pole type 
- 
                                    Bushing Length0.250 inches maximum 
- 
                                    Body Width0.750 inches maximum 
- 
                                    Trip Release Characteristicinstantaneous single location and time delay single location 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts205.0 ac single location and 30.0 dc single location 
- 
                                    Auxiliary Switch Function And Quantity1 control 
- 
                                    Case Materialplastic 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length1.810 inches nominal 
- 
                                    Switch Terminal Typetab, solder lug 
- 
                                    Thread Series Designatorunc 
- 
                                    Reset Methodmanual 
- 
                                    Actuator Position Designationat pole one 
- 
                                    Mounting Surface To Terminal End Distance2.370 inches maximum 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Terminal Type And Quantity2 screw 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    