AS26574
Circuit Breakers
CIRCUIT BREAKER
AS26574
Society Of Automotive Engineers Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Body Width
0.580 inches maximum
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Frequency In Hertz
400.0 single location
 - 
                                    
Body Style
single pole type
 - 
                                    
~1
data on certain environmental and performance
 - 
                                    
Reset Method
manual
 - 
                                    
Actuator Position Designation
at pole one
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
3.0 amperes ac single location and 3.0 amperes dc single location
 - 
                                    
Terminal Type And Quantity
2 screw
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
145.0 single location
 - 
                                    
Thread Quantity Per Inch
32
 - 
                                    
Nominal Thread Size
0.438 inches
 - 
                                    
Circuit Protection Type
overcurrent single location
 - 
                                    
Bushing Length
0.359 inches nominal
 - 
                                    
Trip Release Method
thermal single location
 - 
                                    
Mounting Facility Type And Quantity
1 threaded bushing
 - 
                                    
Manual Actuator Type And Quantity
1 push-pull
 - 
                                    
Pole Quantity
1
 - 
                                    
Case Material
metal
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location
 - 
                                    
Internal Trip Release Configuration
series trip single location
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac single location and 28.0 dc single location
 - 
                                    
Trip Release Characteristic
time delay single location
 - 
                                    
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
 - 
                                    
Body Length
0.780 inches maximum
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
100.0 ac single location and 100.0 dc single location
 - 
                                    
Thread Series Designator
un
 - 
                                    
Inclosure Protection Type For Which Designed
explosion resistant and fungus resistant
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
0.593 inches nominal
 - 
                                    
Mounting Surface To Terminal End Distance
1.420 inches maximum
 - 
                                    
Test Data Document
81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    