Technical Characteristics
- 
                                    
Test Data Document
81349-mil-r-6106 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
 - 
                                    
Fragility Factor
moderately rugged
 - 
                                    
Main Contact Load Current Rating At Maximum Rated Voltage
4.0 amperes ac motor load and 4.0 amperes dc motor load
 - 
                                    
Overall Width
1.531 inches maximum
 - 
                                    
Mounting Facility Type And Quantity
3 unthreaded hole single mounting facility
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Specification/Standard Data
96906-ms25327 government standard
 - 
                                    
Operating Voltage Rating And Type At Specified Temp
115.0 volts ac 25 deg celsius single winding
 - 
                                    
~1
data on certain environmental and performance
 - 
                                    
Environmental Protection
hermetic
 - 
                                    
Arc Quenching Method
air
 - 
                                    
Main Contact Load Current Rating At Maximum Rated Voltage
6.0 amperes ac inductive load and 6.0 amperes dc inductive load
 - 
                                    
Winding Quantity
1
 - 
                                    
Unthreaded Mounting Hole Diameter
0.147 inches nominal single mounting facility
 - 
                                    
Case Material
metal
 - 
                                    
Frequency In Hertz
400.0 nominal
 - 
                                    
Main Contact Load Current Rating At Maximum Rated Voltage
2.0 amperes ac lamp load and 2.0 amperes dc lamp load
 - 
                                    
Cubic Measure
7.219 cubic inches
 - 
                                    
Mounting Facility Pattern
triangle single mounting facility
 - 
                                    
Center To Center Distance Between Mounting Facilities Parallel To The Altitude Of An Isosceles Triangle
1.844 inches nominal single mounting facility
 - 
                                    
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
 - 
                                    
Overall Height
2.156 inches maximum
 - 
                                    
Nonpile-Up Main Contact Arrangement
4 pole, double throw, one position momentary
 - 
                                    
Purpose For Which Designed
general
 - 
                                    
Coil Quantity
1
 - 
                                    
Terminal Type And Quantity
14 pin all functions
 - 
                                    
Overall Length
2.187 inches maximum
 - 
                                    
Time Delay
0.05 seconds maximum fixed release time
 - 
                                    
Duty Type
continuous
 - 
                                    
Time Delay
0.02 seconds maximum fixed operate time
 - 
                                    
Main Contact Load Current Rating At Maximum Rated Voltage
10.0 amperes ac resistive load and 10.0 amperes dc resistive load
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    