Technical Characteristics
- 
                                    Fragility Factormoderately rugged 
- 
                                    Special Handling Featuremagnetic 
- 
                                    Pole Quantity3 
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Body Width2.280 inches maximum 
- 
                                    Thread Series Designatorunc 
- 
                                    Actuator Position Designationat each pole 
- 
                                    Reset Methodmanual 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Trip Release Characteristictime delay all locations 
- 
                                    Actuator Functiontrip-reset 
- 
                                    External Actuator Linkage Arrangementone, two, and three linked 
- 
                                    Internal Trip Release Configurationseries trip all locations 
- 
                                    Maximum Continuous Load Current Rating Per Pole2.5 amperes ac second location 
- 
                                    Inclosure Protection Type For Which Designeddustproof and sand resistant and shockproof and explosion proof and vibrationproof and moisture resistant and salt spray proof 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Trip Release Methodmagnetic-hydraulic all locations 
- 
                                    Body Stylemultipole-multiple actuator type 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length1.800 inches minimum and 1.820 inches maximum 
- 
                                    Mounting Facility Type And Quantity6 threaded hole 
- 
                                    Maximum Continuous Load Current Rating Per Pole2.5 amperes ac third location 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current0.200 minimum at 200 pct all locations and 0.900 maximum at 200 pct all locations 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent150.0 all locations 
- 
                                    Nominal Thread Size0.138 inches 
- 
                                    Center To Center Distance Between Terminals Parallel To Width0.740 inches minimum and 0.760 inches maximum 
- 
                                    Body Length2.520 inches maximum 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Center To Center Distance Between Terminals Parallel To Length1.200 inches maximum 
- 
                                    Arc Quenching Methodmagnetic blowout 
- 
                                    Mounting Surface To Terminal End Distance2.010 inches maximum 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Width0.740 inches minimum and 0.760 inches maximum 
- 
                                    Bushing Length0.130 inches maximum 
- 
                                    Frequency In Hertz400.0 all locations 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts120.0 ac all locations 
- 
                                    Case Materialmica 
- 
                                    Unpackaged Unit Weight0.810 pounds 
- 
                                    Terminal Type And Quantity6 tab w/screw 
- 
                                    Manual Actuator Type And Quantity3 toggle 
- 
                                    Maximum Continuous Load Current Rating Per Pole3.0 amperes ac first location 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps3500.0 ac all locations 