382-2074-2
Circuit Breakers
CIRCUIT BREAKER
382-2074-2
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Body Length
1.313 inches minimum and 1.375 inches maximum
 - 
                                    
Bushing Length
0.250 inches nominal
 - 
                                    
Reset Method
manual
 - 
                                    
Thread Series Designator
unf
 - 
                                    
Ultimate Trip Time Per Pole In Seconds
60.000 nominal single location
 - 
                                    
Circuit Protection Type
overcurrent single location
 - 
                                    
Trip Release Method
thermal single location
 - 
                                    
Mounting Facility Type And Quantity
1 threaded bushing
 - 
                                    
Pole Quantity
1
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Nominal Thread Size
0.138 inches
 - 
                                    
Trip Release Characteristic
time delay single location
 - 
                                    
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac single location and 4000.0 dc single location
 - 
                                    
Mounting Surface To Terminal End Distance
1.250 inches minimum and 1.312 inches maximum
 - 
                                    
Body Style
single pole type
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
0.906 inches nominal
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac single location and 20.0 amperes dc single location
 - 
                                    
Terminal Type And Quantity
2 tab w/screw
 - 
                                    
Internal Trip Release Configuration
series trip w/auxiliary load terminal and remote trip feature single location
 - 
                                    
Body Width
0.688 inches minimum and 0.750 inches maximum
 - 
                                    
Case Material
plastic
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    