9999-9300
Circuit Breakers
CIRCUIT BREAKER
9999-9300
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Thread Series Designator
unef
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
0.844 inches minimum and 0.906 inches maximum
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
0.070 minimum at 200 pct all locations and 0.700 maximum at 200 pct all locations
 - 
                                    
Unpackaged Unit Weight
5.400 ounces
 - 
                                    
Terminal Type And Quantity
6 wire hook
 - 
                                    
Internal Trip Release Configuration
relay trip first location
 - 
                                    
Bushing Length
0.380 inches maximum
 - 
                                    
Special Handling Feature
magnetic
 - 
                                    
Fragility Factor
moderately rugged
 - 
                                    
Frequency In Hertz
400.0 all locations
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac third location
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
 - 
                                    
Body Length
1.562 inches maximum
 - 
                                    
Inclosure Protection Type For Which Designed
moisture resistant and fungus resistant and hermetically sealed
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Body Width
1.937 inches maximum
 - 
                                    
Internal Trip Release Configuration
series trip third location
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Internal Trip Release Configuration
series trip second location
 - 
                                    
Case Material
metal
 - 
                                    
Body Style
multipole-single actuator type
 - 
                                    
Actuator Position Designation
at pole two
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
500.0 milliamperes ac first location
 - 
                                    
Mounting Surface To Terminal End Distance
1.780 inches maximum
 - 
                                    
Trip Release Method
magnetic-hydraulic all locations
 - 
                                    
Thread Quantity Per Inch
32
 - 
                                    
Nominal Thread Size
0.375 inches
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Trip Release Characteristic
time delay all locations
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
 - 
                                    
Center To Center Distance Between Terminals Parallel To Width
0.594 inches minimum and 0.656 inches maximum
 - 
                                    
Reset Method
manual
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac second location
 - 
                                    
Circuit Protection Type
overcurrent all locations
 - 
                                    
Pole Quantity
3
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    