MS27401-2
Relays and Solenoids
RELAY,ELECTROMAGNETIC
MS27401-2
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Cubic Measure
0.910 cubic inches
-
Main Contact Load Current Rating At Maximum Rated Voltage
4.0 amperes ac motor load and 4.0 amperes dc motor load
-
Overall Height
1.010 inches maximum
-
Storage Type
general purpose warehouse
-
Time Delay
0.01 seconds maximum fixed operate and release time
-
Nonpile-Up Main Contact Arrangement
2 pole, double throw, one position momentary
-
Precious Material
gold
-
Precious Material And Location
terminal surfaces gold
-
Test Data Document
81349-mil-r-6106 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Overall Width
0.525 inches maximum
-
Terminal Type And Quantity
8 pin all functions
-
Purpose For Which Designed
general
-
Operating Voltage Rating And Type At Specified Temp
28.0 volts dc 25 deg celsius single winding
-
Coil Quantity
1
-
Main Contact Load Current Rating At Maximum Rated Voltage
8.0 amperes ac inductive load and 8.0 amperes dc inductive load
-
Duty Type
continuous
-
Environmental Protection
hermetic
-
Mounting Slot Width
0.150 inches nominal single mounting facility
-
Winding Dc Resistance Rating
320.0 ohms nominal single winding
-
Arc Quenching Method
air
-
Mounting Facility Type And Quantity
2 slotted hole single mounting facility
-
Winding Quantity
1
-
Overall Length
1.718 inches maximum
-
Case Material
metal
-
Main Contact Load Current Rating At Maximum Rated Voltage
2.0 amperes ac lamp load and 2.0 amperes dc lamp load
-
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Specification/Standard Data
96906-ms27401 government standard
-
~1
data on certain environmental and performance
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.446 inches nominal single mounting facility
-
Mounting Facility Pattern
in-line single mounting facility
-
Main Contact Load Current Rating At Maximum Rated Voltage
10.0 amperes ac resistive load and 10.0 amperes dc resistive load
Related Parts by Category
Related Parts by Manufacturer
Certified toAS6081 Methods