AM3333MG6-5-5-15-15-250-5-60
Circuit Breakers
CIRCUIT BREAKER
AM3333MG6-5-5-15-15-250-5-60
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac fourth location
-
Internal Trip Release Configuration
series trip all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Thread Quantity Per Inch
32
-
Mounting Facility Type And Quantity
8 threaded hole
-
Trip Release Method
magnetic-hydraulic all locations
-
Body Style
multipole-multiple actuator type
-
External Actuator Linkage Arrangement
one, two, three, and four linked
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Terminal Type And Quantity
8 threaded stud
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
-
Nominal Thread Size
0.138 inches
-
Storage Type
general purpose warehouse
-
Center To Center Distance Between Terminals Parallel To Length
1.928 inches minimum and 1.948 inches maximum
-
Mounting Surface To Terminal End Distance
2.461 inches minimum and 2.481 inches maximum
-
Reset Method
manual
-
Actuator Position Designation
at each pole
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac second location
-
Thread Series Designator
unc
-
Circuit Protection Type
overcurrent all locations
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac first location
-
Fragility Factor
moderately rugged
-
Center To Center Distance Between Terminals Parallel To Width
0.740 inches minimum and 0.760 inches maximum
-
Frequency In Hertz
60.0 all locations
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Unpackaged Unit Weight
1.062 pounds
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.052 inches minimum and 2.072 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.740 inches minimum and 0.760 inches maximum
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Body Width
2.990 inches minimum and 3.010 inches maximum
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac third location
-
Body Length
2.490 inches minimum and 2.510 inches maximum
-
Manual Actuator Type And Quantity
4 toggle
-
Boss Height
0.130 inches minimum and 0.150 inches maximum
-
Case Material
plastic
-
Pole Quantity
4
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.250 minimum at 200 pct all locations and 1.000 maximum at 200 pct all locations
Related Parts by Category
Related Parts by Manufacturer


AS6081 Methods