3179574-18
Circuit Breakers
CIRCUIT BREAKER
3179574-18
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.200 minimum at 200 pct all locations and 6.000 maximum at 200 pct all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac all locations
-
Case Material
plastic
-
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac all locations
-
Fragility Factor
moderately rugged
-
Special Handling Feature
magnetic
-
Center To Center Distance Between Terminals Parallel To Width
0.687 inches nominal
-
Auxiliary Switch Function And Quantity
1 alarm
-
Switch Voltage Rating And Type In Volts
120.0 ac and 50.0 dc
-
Thread Series Designator
unef
-
Nonturn Device Diameter
0.180 inches minimum and 0.300 inches maximum
-
Switch Terminal Type
pin
-
Frequency In Hertz
400.0 all locations
-
Center To Center Distance Between Terminals Parallel To Length
0.906 inches maximum
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 all locations
-
Body Length
1.562 inches maximum
-
Switch Current Rating And Type In Amps
0.5 ac and 0.5 dc
-
Arc Quenching Method
magnetic blowout
-
Main Contact Tripping Mechanism Type
trip free
-
Actuator Position Designation
between pole one and two
-
Body Width
1.937 inches maximum
-
Manual Actuator Type And Quantity
1 toggle
-
Nonturn Device Radius
0.625 inches nominal
-
Body Style
multipole-single actuator type
-
Switch Contact Arrangement
single pole, double throw
-
Terminal Type And Quantity
4 wire hook
-
Trip Release Method
magnetic all locations
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
-
Thread Quantity Per Inch
32
-
Nominal Thread Size
0.375 inches
-
Nonturn Device Location
at 12 oclock
-
Internal Trip Release Configuration
series trip all locations
-
Mounting Surface To Terminal End Distance
1.828 inches maximum
-
Actuator Function
trip-reset
-
Trip Release Characteristic
time delay all locations
-
Switch Location And Position Designation
internal at pole two
-
Storage Type
general purpose warehouse
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Reset Method
manual
-
Pole Quantity
2
-
Test Data Document
10001-3179574 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Bushing Length
0.280 inches minimum and 0.380 inches maximum
-
Circuit Protection Type
overcurrent all locations
-
Inclosure Protection Type For Which Designed
shock resistant and fungus resistant and vibration resistant and moisture resistant and salt spray proof
Related Parts by Category
Related Parts by Manufacturer


AS6081 Methods