M39019/05-218
Circuit Breakers
CIRCUIT BREAKER
M39019/05-218
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Test Data Document
81349-mil-c-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
~1
data on certain environmental and performanc
-
Inclosure Protection Type For Which Designed
fungus resistant and hermetically sealed
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations and 50.0 dc all locations
-
Nominal Thread Size
0.375 inches
-
Thread Quantity Per Inch
32
-
Body Length
1.531 inches minimum and 1.562 inches maximum
-
Trip Release Method
magnetic all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Unpackaged Unit Weight
150.0 grams
-
Actuator Position Designation
at pole two
-
Body Style
multipole-single actuator type
-
Case Material
metal
-
Manual Actuator Type And Quantity
1 toggle
-
Main Contact Tripping Mechanism Type
trip free
-
Body Width
1.906 inches minimum and 1.937 inches maximum
-
Frequency In Hertz
400.0 all locations
-
Thread Series Designator
unef
-
Mounting Surface To Terminal End Distance
1.797 inches minimum and 1.828 inches maximum
-
Specification/Standard Data
81349-mil-c-39019/5 government specification
-
Terminal Type And Quantity
6 wire hook
-
Fragility Factor
moderately rugged
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac all locations and 2.0 amperes dc all locations
-
Bushing Length
0.332 inches minimum and 0.380 inches maximum
-
Reset Method
manual
-
Center To Center Distance Between Terminals Parallel To Width
0.594 inches minimum and 0.656 inches maximum
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.055 minimum at 200 pct all locations and 0.950 maximum at 200 pct all locations
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Internal Trip Release Configuration
series trip all locations
-
Center To Center Distance Between Terminals Parallel To Length
0.875 inches minimum and 0.906 inches maximum
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac all locations and 500.0 dc all locations
Related Parts by Category
Related Parts by Manufacturer
Certified toAS6081 Methods