Technical Characteristics

  • Trip Release Method

    thermal all locations

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    5.250 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    480.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    18000.0 ac all locations

  • Unthreaded Mounting Hole Diameter

    0.188 inches nominal

  • Boss Height

    0.125 inches nominal

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Main Contact Tripping Mechanism Type

    trip free

  • Terminal Type And Quantity

    6 compression

  • Frequency In Hertz

    60.0 all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.880 inches nominal

  • Body Style

    multipole-single actuator type

  • Actuator Position Designation

    at pole two

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Center To Center Distance Between Terminals Parallel To Width

    1.380 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.380 inches nominal

  • Internal Trip Release Configuration

    series trip all locations

  • Body Height

    3.380 inches nominal

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.020 minimum at 200 pct all locations and 4.500 maximum at 200 pct all locations

  • Body Length

    6.310 inches nominal

  • Reset Method

    manual

  • Body Width

    4.125 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    90.0 amperes ac all locations

  • Inclosure Protection Type For Which Designed

    dustproof

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...