SM333-0-5-240VAC400C1
Circuit Breakers
CIRCUIT BREAKER
SM333-0-5-240VAC400C1
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac all locations and 500.0 dc all locations
-
Thread Pitch Diameters
+0.3503/+0.3537 inches
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations and 50.0 dc all locations
-
Nominal Thread Size
0.375 inches
-
Thread Quantity Per Inch
32
-
Trip Release Method
magnetic all locations
-
Unpackaged Unit Weight
150.0 grams
-
Actuator Position Designation
at pole two
-
Body Style
multipole-single actuator type
-
Case Material
metal
-
Manual Actuator Type And Quantity
1 toggle
-
Body Width
1.937 inches maximum
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
-
Arc Quenching Method
magnetic blowout
-
Body Length
1.562 inches maximum
-
Specification/Standard Data
81349-mil-prf-39019/5 government specification
-
Center To Center Distance Between Terminals Parallel To Length
0.906 inches maximum
-
Frequency In Hertz
400.0 all locations
-
Thread Series Designator
unef
-
Center To Center Distance Between Terminals Parallel To Width
0.687 inches nominal
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.500 minimum at 200 pct all locations and 9.000 maximum at 200 pct all locations
-
Terminal Type And Quantity
6 wire hook
-
Bushing Length
0.380 inches maximum
-
Test Data Document
81349-mil-prf-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general
-
~1
type data on certain environmental and performa
-
Maximum Continuous Load Current Rating Per Pole
500.0 milliamperes ac all locations and 500.0 milliamperes dc all locations
-
Internal Trip Release Configuration
series trip all locations
-
Mounting Surface To Terminal End Distance
1.828 inches maximum
-
Actuator Function
trip-reset
-
Trip Release Characteristic
time delay all locations
-
Storage Type
general purpose warehouse
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Reset Method
manual
-
Circuit Protection Type
overcurrent all locations
-
Pole Quantity
3
-
Special Handling Feature
magnetic
-
Fragility Factor
moderately rugged
-
Inclosure Protection Type For Which Designed
hermetically sealed and fungus resistant and moisture resistant and vibration resistant and shock resistant and salt spray proof
Related Parts by Category
Related Parts by Manufacturer


AS6081 Methods