M39019/03-234
Circuit Breakers
CIRCUIT BREAKER
M39019/03-234
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Surface To Terminal End Distance
1.797 inches minimum and 1.828 inches maximum
-
Thread Series Designator
unef
-
Frequency In Hertz
400.0 all locations
-
Unpackaged Unit Weight
100.0 grams
-
Specification/Standard Data
81349-mil-prf-39019/3 government specification
-
Main Contact Tripping Mechanism Type
trip free
-
Actuator Position Designation
between pole one and two
-
Manual Actuator Type And Quantity
1 toggle
-
Case Material
metal
-
Body Style
multipole-single actuator type
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations and 50.0 dc all locations
-
Terminal Type And Quantity
4 wire hook
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Maximum Continuous Load Current Rating Per Pole
6.0 amperes ac all locations and 6.0 amperes dc all locations
-
Trip Release Method
magnetic all locations
-
Body Length
1.531 inches minimum and 1.562 inches maximum
-
Thread Quantity Per Inch
32
-
Nominal Thread Size
0.375 inches
-
Inclosure Protection Type For Which Designed
fungus resistant and hermetically sealed
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac all locations and 500.0 dc all locations
-
Center To Center Distance Between Terminals Parallel To Length
0.875 inches minimum and 0.906 inches maximum
-
Internal Trip Release Configuration
series trip all locations
-
Actuator Function
trip-reset
-
Trip Release Characteristic
time delay all locations
-
Storage Type
general purpose warehouse
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Center To Center Distance Between Terminals Parallel To Width
0.594 inches minimum and 0.656 inches maximum
-
Reset Method
manual
-
Bushing Length
0.332 inches minimum and 0.380 inches maximum
-
Pole Quantity
2
-
Circuit Protection Type
overcurrent all locations
-
Test Data Document
81349-mil-prf-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general
-
~1
type data on certain environmental and performa
-
Body Width
1.250 inches minimum and 1.281 inches maximum
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.500 minimum at 200 pct all locations and 9.000 maximum at 200 pct all locations
Related Parts by Category
Related Parts by Manufacturer


AS6081 Methods