Technical Characteristics
- 
                                    
Body Width
2.230 inches nominal
 - 
                                    
Body Height
2.650 inches nominal
 - 
                                    
Case Material
plastic
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
10000.0 ac all locations
 - 
                                    
Trip Release Method
thermal-magnetic all locations
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Trip Release Ambient Temp Rating
50.0 deg celsius nominal all locations
 - 
                                    
Terminal Type And Quantity
3 clip and 3 compression
 - 
                                    
Body Style
20b multipole-single actuator type
 - 
                                    
Body Length
6.250 inches nominal
 - 
                                    
Center To Center Distance Between Terminals Parallel To Width
0.780 inches nominal
 - 
                                    
Fragility Factor
moderately rugged
 - 
                                    
Boss Height
0.250 inches nominal
 - 
                                    
Pole Quantity
3
 - 
                                    
Mounting Facility Type And Quantity
3 terminal
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
70.0 amperes ac all locations
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
 - 
                                    
Circuit Protection Type
overcurrent all locations
 - 
                                    
Trip Release Characteristic
time delay all locations
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
 - 
                                    
Reset Method
manual
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Actuator Position Designation
at pole two
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
360.000 maximum at 200 pct all locations
 - 
                                    
Inclosure Protection Type For Which Designed
fungus resistant
 - 
                                    
Frequency In Hertz
60.0 all locations
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    