FA-14040-A
Circuit Breakers
CIRCUIT BREAKER
FA-14040-A
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Pole Quantity
1
 - 
                                    
Body Height
3.500 inches nominal
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Trip Release Method
thermal-magnetic single location
 - 
                                    
Trip Release Characteristic
time delay single location
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Boss Height
0.125 inches nominal
 - 
                                    
Body Style
single pole type
 - 
                                    
Body Length
6.000 inches nominal
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
 - 
                                    
Frequency In Hertz
60.0 single location
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
30.000 minimum at 200 pct single location and 100.000 maximum at 200 pct single location
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
40.0 amperes ac single location
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
10000.0 ac single location
 - 
                                    
Body Width
1.500 inches nominal
 - 
                                    
Terminal Type And Quantity
1 quick disconnect, female and 1 compression
 - 
                                    
Case Material
plastic
 - 
                                    
Reset Method
manual
 - 
                                    
Actuator Position Designation
at pole one
 - 
                                    
Mounting Facility Type And Quantity
1 terminal
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Trip Release Ambient Temp Rating
40.0 deg celsius nominal single location
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
480.0 ac single location
 - 
                                    
Circuit Protection Type
overcurrent single location
 - 
                                    
Inclosure Protection Type For Which Designed
fungus resistant
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    