M39019/02-257
Circuit Breakers
CIRCUIT BREAKER
M39019/02-257
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Trip Release Method
magnetic single location
-
Terminal Type And Quantity
2 wire hook
-
Switch Terminal Type
tab, solder lug
-
Bushing Length
0.332 inches minimum and 0.380 inches maximum
-
Reset Method
manual
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Center To Center Distance Between Terminals Parallel To Length
0.875 inches minimum and 0.906 inches maximum
-
Thread Pitch Diameters
+0.3503/+0.3537 inches
-
Inclosure Protection Type For Which Designed
fungus resistant and hermetically sealed
-
Nominal Thread Size
0.375 inches
-
~1
data on certain environmental and performanc
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.055 minimum at 200 pct single location and 0.950 maximum at 200 pct single location
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac single location and 50.0 dc single location
-
Switch Location And Position Designation
internal at pole one
-
Test Data Document
81349-mil-c-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Thread Quantity Per Inch
32
-
Body Length
1.531 inches minimum and 1.562 inches maximum
-
Circuit Protection Type
overcurrent single location
-
Body Width
0.594 inches minimum and 0.625 inches maximum
-
Switch Contact Arrangement
single pole, double throw
-
Pole Quantity
1
-
Case Material
metal
-
Manual Actuator Type And Quantity
1 toggle
-
Internal Trip Release Configuration
series trip single location
-
Specification/Standard Data
81349-mil-c-39019/2 government specification
-
Trip Release Characteristic
time delay single location
-
Main Contact Tripping Mechanism Type
trip free
-
Switch Current Rating And Type In Amps
0.5 ac and 0.5 dc
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 single location
-
Frequency In Hertz
400.0 single location
-
Body Style
single pole type
-
Mounting Surface To Terminal End Distance
1.669 inches minimum and 1.700 inches maximum
-
Thread Series Designator
unef
-
Switch Voltage Rating And Type In Volts
120.0 ac and 50.0 dc
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac single location and 20.0 amperes dc single location
-
Unpackaged Unit Weight
50.0 grams
-
Auxiliary Switch Function And Quantity
1 alarm
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac single location and 500.0 dc single location
Related Parts by Category
Related Parts by Manufacturer
Certified toAS6081 Methods