                                    Test Data Document81349-mil-c-5859 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type 
- 
                                    ~1data on certain environmental and performance 
- 
                                    Frequency In Hertz400.0 single location 
- 
                                    Maximum Continuous Load Current Rating Per Pole15.0 amperes ac single location and 15.0 amperes dc single location 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Trip Release Ambient Temp Rating25.0 deg celsius nominal single location 
- 
                                    Trip Release Characteristictime delay single location 
- 
                                    Nominal Thread Size0.138 inches 
- 
                                    Internal Trip Release Configurationseries trip single location 
- 
                                    Body Length2.189 inches maximum 
- 
                                    Specification/Standard Data96906-ms25244 government standard 
- 
                                    Pole Quantity1 
- 
                                    Inclosure Protection Type For Which Designedfungus resistant 
- 
                                    Manual Actuator Type And Quantity1 push-pull 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current15.000 minimum at 200 pct single location and 55.000 maximum at 200 pct single location 
- 
                                    Trip Release Methodthermal single location 
- 
                                    Circuit Protection Typeovercurrent single location 
- 
                                    Mounting Surface To Terminal End Distance2.000 inches maximum 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Mounting Facility Type And Quantity2 threaded hole 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Actuator Position Designationat pole one 
- 
                                    Reset Methodmanual 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length1.812 inches nominal 
- 
                                    Thread Series Designatorunc 
- 
                                    Case Materialplastic 
- 
                                    Body Width0.750 inches maximum 
- 
                                    Terminal Type And Quantity2 tab w/screw 
- 
                                    Unpackaged Unit Weight1.600 ounces 
- 
                                    Bushing Length0.265 inches maximum 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent138.0 single location 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts120.0 ac single location and 30.0 dc single location 
- 
                                    Body Stylesingle pole type 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps3500.0 ac single location and 6000.0 dc single location 
- 
                                    Center To Center Distance Between Terminals Parallel To Length0.704 inches nominal 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    