40771-001
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
40771-001
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Overall Length
4.120 inches maximum
 - 
                                    
Body Length
3.120 inches maximum
 - 
                                    
Body Height
4.500 inches maximum
 - 
                                    
Unthreaded Mounting Hole Diameter
0.221 inches nominal
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
2.250 inches nominal
 - 
                                    
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference .
 - 
                                    
Load Impedance Per Function
50.0 ohms 2nd radio interference .
 - 
                                    
Load Impedance Per Function
50.0 ohms 3rd radio interference .
 - 
                                    
Input Terminal Identification
ms3102r-18-11p
 - 
                                    
Distance Between Mounting Surface And Lower End
0.880 inches nominal
 - 
                                    
Functional Terminal Type And Quantity
1 connector, receptacle input .
 - 
                                    
Functional Terminal Type And Quantity
3 threaded stud output .
 - 
                                    
Operating Voltage Rating And Type Per Function
440.0 volts ac 1st radio interference .
 - 
                                    
Operating Voltage Rating And Type Per Function
440.0 volts ac 2nd radio interference .
 - 
                                    
Style Designator
16 rectangular terminal/terminals on opposite surfaces
 - 
                                    
Body Width
3.380 inches maximum
 - 
                                    
Source Impedance Rating Per Function
50.0 ohms 1st radio interference .
 - 
                                    
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference .
 - 
                                    
Load Impedance Per Function
50.0 ohms 1st radio interference .
 - 
                                    
Power Line Frequency Rating Per Function In Hertz
60.0 1st radio interference .
 - 
                                    
Power Line Frequency Rating Per Function In Hertz
60.0 2nd radio interference .
 - 
                                    
Power Line Frequency Rating Per Function In Hertz
60.0 3rd radio interference .
 - 
                                    
Operating Current Rating Per Function In Amps
2.5 1st radio interference .
 - 
                                    
Operating Current Rating Per Function In Amps
2.5 2nd radio interference .
 - 
                                    
Operating Current Rating Per Function In Amps
2.5 3rd radio interference .
 - 
                                    
Input Terminal Manufacturer Code
96906
 - 
                                    
Inclosure Type
encased
 - 
                                    
Mounting Facility Type And Quantity
6 unthreaded hole
 - 
                                    
Functional Terminal Type And Quantity
1 threaded stud ground .
 - 
                                    
Operating Voltage Rating And Type Per Function
440.0 volts ac 3rd radio interference .
 - 
                                    
Body Material
metal
 - 
                                    
Body Surface Treatment
tin
 
Related Parts by Category