HE2-Z16-2
Circuit Breakers
CIRCUIT BREAKER
HE2-Z16-2
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Maximum Continuous Load Current Rating Per Pole
50.0 milliamperes ac second location
-
Bushing Length
0.380 inches maximum
-
Thread Series Designator
unef
-
Body Width
1.250 inches maximum
-
Unpackaged Unit Weight
3.600 ounces
-
Arc Quenching Method
magnetic blowout
-
Main Contact Tripping Mechanism Type
trip free
-
Inclosure Protection Type For Which Designed
vibration resistant and hermetically sealed and shock resistant
-
Actuator Position Designation
between pole one and two
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Reset Method
manual
-
Pole Quantity
2
-
Circuit Protection Type
overcurrent all locations
-
Special Handling Feature
magnetic
-
Nonturn Device Diameter
0.250 inches nominal
-
Fragility Factor
moderately rugged
-
Body Length
1.500 inches maximum
-
Frequency In Hertz
60.0 all locations
-
Manual Actuator Type And Quantity
1 toggle
-
Case Material
metal
-
Nonturn Device Radius
0.625 inches nominal
-
Body Style
multipole-single actuator type
-
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac first location
-
Center To Center Distance Between Terminals Parallel To Length
0.875 inches nominal
-
Terminal Type And Quantity
4 wire hook
-
Mounting Surface To Terminal End Distance
1.780 inches maximum
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Trip Release Method
magnetic all locations
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
-
Thread Quantity Per Inch
32
-
Nominal Thread Size
0.375 inches
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Internal Trip Release Configuration
series trip all locations
-
Actuator Function
trip-reset
-
Center To Center Distance Between Terminals Parallel To Width
0.625 inches nominal
-
Trip Release Characteristic
time delay all locations
-
Storage Type
general purpose warehouse
-
Nonturn Device Length
0.140 inches nominal
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.500 minimum at 200 pct all locations and 11.000 maximum at 200 pct all locations
Related Parts by Category
Related Parts by Manufacturer


AS6081 Methods