W67X1S7230
Circuit Breakers
CIRCUIT BREAKER
W67X1S7230
Wood Electric Operations Potter And
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Length
1.990 inches minimum and 2.010 inches maximum
-
Body Width
0.740 inches minimum and 0.760 inches maximum
-
Case Material
plastic
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.650 inches minimum and 1.670 inches maximum
-
Boss Height
0.120 inches minimum and 0.140 inches maximum
-
Pole Quantity
1
-
Arc Quenching Method
magnetic blowout
-
Mounting Facility Type And Quantity
2 threaded hole
-
Storage Type
general purpose warehouse
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
30.0 amperes dc
-
Operating Voltage Type And Rating Per Pole In Volts
32.0 dc
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc
-
Internal Trip Release Configuration
series trip
-
Nominal Thread Size
0.138 inches
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant and humidity resistant and shock resistant and vibration resistant
-
Thread Series Designator
unc
-
Terminal Type And Quantity
2 tab w/screw
-
Center To Center Distance Between Terminals Parallel To Length
1.550 inches minimum and 1.570 inches maximum
-
Fragility Factor
moderately rugged
-
Mounting Surface To Terminal End Distance
1.935 inches minimum and 1.955 inches maximum
-
Circuit Protection Type
overcurrent
-
Trip Release Method
magnetic-hydraulic
-
Trip Release Characteristic
time delay
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Function
trip-reset
-
Actuator Position Designation
at pole one
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.600 minimum at 200 pct and 8.000 maximum at 200 pct
Related Parts by Category
Related Parts by Manufacturer
Certified toAS6081 Methods