MS27400-6U
Relays and Solenoids
RELAY,ELECTROMAGNETIC
MS27400-6U
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Storage Type
general purpose warehouse
-
Criticality Code Justification
feat
-
Time Delay
0.015 seconds maximum fixed operate and release time
-
Cubic Measure
2.254 cubic inches
-
Precious Material
gold
-
Precious Material And Location
terminal surfaces gold
-
Purpose For Which Designed
specific
-
Environmental Protection
hermetic
-
Mounting Slot Width
0.150 inches nominal single mounting facility
-
Specification/Standard Data
81349--83536/15-022m government specification
-
Arc Quenching Method
air
-
Winding Quantity
1
-
Overall Length
1.718 inches maximum
-
Mounting Facility Type And Quantity
3 slotted hole single mounting facility
-
Case Material
metal
-
Features Provided
polarized
-
Main Contact Load Current Rating At Maximum Rated Voltage
2.0 amperes ac lamp load and 2.0 amperes dc lamp load
-
Mounting Facility Pattern
triangle single mounting facility
-
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Nonpile-Up Main Contact Arrangement
4 pole, double throw, one position momentary
-
Overall Width
1.025 inches maximum
-
Operating Voltage Rating And Type At Specified Temp
28.0 volts dc 25 deg celsius single winding
-
~1
reflecting general type data on certain environmental
-
Test Data Document
81349-mil-r-83536 specification specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications,
-
Special Features
failure rate level 1 persent per 10,000 cycles
-
Coil Quantity
1
-
Terminal Type And Quantity
14 pin all functions
-
Winding Dc Resistance Rating
290.0 ohms nominal single winding
-
Main Contact Load Current Rating At Maximum Rated Voltage
8.0 amperes ac inductive load and 8.0 amperes dc inductive load
-
Duty Type
continuous
-
Center To Center Distance Between Mounting Facilities Parallel To Width
0.625 inches nominal single mounting facility
-
Main Contact Load Current Rating At Maximum Rated Voltage
10.0 amperes ac resistive load and 10.0 amperes dc resistive load
-
Fragility Factor
moderately rugged
-
Nominal Operating Current Rating And Type
120.0 milliamperes dc single winding
-
Main Contact Load Current Rating At Maximum Rated Voltage
4.0 amperes ac motor load and 4.0 amperes dc motor load
-
Overall Height
1.280 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To The Altitude Of An Isosceles Triangle
1.421 inches nominal single mounting facility
Related Parts by Category
Related Parts by Manufacturer


AS6081 Methods