4989D52G07

Circuit Breakers

CIRCUIT BREAKER

4989D52G07

5925-01-092-6288

5925 - Circuit Breakers

Eaton Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Width

    1.375 inches nominal

  • Case Material

    plastic

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    4 slot

  • Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    40.0 amperes ac single location

  • Operating Voltage Type And Rating Per Pole In Volts

    480.0 ac single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    14000.0 ac single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Trip Delay Time In Seconds Per Rated Continuous Current

    4.000 maximum at 200 pct single location

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal single location

  • Terminal Type And Quantity

    2 compression

  • Specification/standard Data

    81348-w-c-375/16 government specification

  • Body Style

    9a single pole type

  • Mounting Slot Width

    0.094 inches nominal

  • Body Length

    6.000 inches nominal

  • Body Height

    3.375 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    4.000 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.500 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.000 inches nominal

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.125 inches nominal

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal-magnetic single location

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Inclosure Protection Type For Which Designed

    corrosion resistant

  • Frequency In Hertz

    60.0

  • Test Data Document

    81348-w-c-375 specification

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...