76-11481
Relays and Solenoids
RELAY,ELECTROMAGNETIC
76-11481
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Overall Width1.010 inches maximum 
- 
                                    Case Materialmetal 
- 
                                    Main Contact Load Current Rating At Maximum Rated Voltage2.0 amperes ac lamp load and 2.0 amperes dc lamp load 
- 
                                    Terminal Type And Quantity8 wire hook all functions 
- 
                                    Main Contact Maximum Voltage Rating In Volts115.0 ac and 28.0 dc 
- 
                                    Specification/Standard Data96906-ms27401 government standard 
- 
                                    Special Featuresfailure rate level 0.5 percent per 1000 operations 
- 
                                    Purpose For Which Designedgeneral 
- 
                                    Operating Voltage Rating And Type At Specified Temp28.0 volts dc 25 deg celsius single winding 
- 
                                    Coil Quantity1 
- 
                                    Overall Height0.525 inches maximum 
- 
                                    Main Contact Load Current Rating At Maximum Rated Voltage8.0 amperes ac inductive load and 8.0 amperes dc inductive load 
- 
                                    Duty Typecontinuous 
- 
                                    Center To Center Distance Between Mounting Facilities Parallel To Length1.446 inches nominal single mounting facility 
- 
                                    Mounting Facility Patternin-line single mounting facility 
- 
                                    Main Contact Load Current Rating At Maximum Rated Voltage10.0 amperes ac resistive load and 10.0 amperes dc resistive load 
- 
                                    Cubic Measure0.910 cubic inches 
- 
                                    Main Contact Load Current Rating At Maximum Rated Voltage4.0 amperes ac motor load and 4.0 amperes dc motor load 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Criticality Code Justificationfeat 
- 
                                    Time Delay0.01 seconds maximum fixed operate and release time 
- 
                                    Nonpile-Up Main Contact Arrangement2 pole, double throw, one position momentary 
- 
                                    Environmental Protectionhermetic 
- 
                                    Mounting Slot Width0.150 inches nominal single mounting facility 
- 
                                    Winding Dc Resistance Rating320.0 ohms nominal single winding 
- 
                                    Arc Quenching Methodair 
- 
                                    Mounting Facility Type And Quantity2 slotted hole single mounting facility 
- 
                                    Winding Quantity1 
- 
                                    Overall Length1.718 inches maximum 
- 
                                    ~1data on certain environmental and performance 
- 
                                    Fragility Factormoderately rugged 
- 
                                    Test Data Document81349-mil-r-6106 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    