262413-12
Filters and Networks
FILTER,BAND PASS
262413-12
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Discrimination At Specified Frequencies Per Function In Decibels
3.0 minimum 3rd band pass and 30.0 maximum 3rd band pass
 - 
                                    
Special Features
electrostatic shield brought out to terminal six
 - 
                                    
Load Impedance Per Function
600.0 ohms 3rd band pass
 - 
                                    
Reference Frequency Per Function
2.295 single radio interference two phase to three phase
 - 
                                    
Source Impedance Rating Per Function
600.0 ohms 3rd band pass
 - 
                                    
Frequency Band Width Per Function
2.27375 kilohertz 2nd band pass and 2.31625 kilohertz 2nd band pass
 - 
                                    
Principal Circuitry Type Per Function
inductance-capacitance 2nd band pass
 - 
                                    
Frequency Band Width Per Function
2.27375 kilohertz 3rd band pass and 2.31625 kilohertz 3rd band pass
 - 
                                    
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 3rd band pass
 - 
                                    
Specified Frequencies Of Discrimination Per Function
2.27375 kilohertz 2nd band pass and 2.2525 kilohertz 2nd band pass and 2.31625 kilohertz 2nd band pass and 2.3375 kilohertz 2nd band pass
 - 
                                    
Reference Frequency Per Function
2.295 single radio interference two phase to two phase
 - 
                                    
Body Height
2.950 inches nominal
 - 
                                    
Discrimination At Specified Frequencies Per Function In Decibels
3.0 minimum 2nd band pass and 30.0 maximum 2nd band pass
 - 
                                    
Style Designator
rectangular terminal/terminals on one surface
 - 
                                    
Operating Temp Range
-55.0/+65.0 deg celsius
 - 
                                    
Principal Circuitry Type Per Function
inductance-capacitance 3rd band pass
 - 
                                    
Vibration Resistance Range In Hertz
+10.0/+500.0
 - 
                                    
Maximum Dielectric Withstanding Dc Voltage
500.0 volts at sea level
 - 
                                    
Body Length
3.000 inches nominal
 - 
                                    
Average Life Rating In Hours
10000.0
 - 
                                    
Nominal Thread Size
0.138 inches
 - 
                                    
Specified Frequencies Of Discrimination Per Function
2.31625 kilohertz 3rd band pass and 2.2525 kilohertz 3rd band pass and 2.27375 kilohertz 3rd band pass and 2.3375 kilohertz 3rd band pass
 - 
                                    
Mounting Facility Type And Quantity
2 threaded stud
 - 
                                    
Features Provided
electrostatic shield
 - 
                                    
Mounting Facility Screw Thread Series Designator
unc
 - 
                                    
Functional Terminal Type And Quantity
2 turret input 1st function
 - 
                                    
Load Impedance Per Function
600.0 ohms 1st band pass
 - 
                                    
Specified Frequencies Of Discrimination Per Function
2.27375 kilohertz 1st band pass and 2.2525 kilohertz 1st band pass and 2.31625 kilohertz 1st band pass and 2.3375 kilohertz 1st band pass
 - 
                                    
Source Impedance Rating Per Function
600.0 ohms 1st band pass
 - 
                                    
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 1st band pass
 - 
                                    
Principal Circuitry Type Per Function
inductance-capacitance 1st band pass
 - 
                                    
Inclosure Type
hermetically sealed
 - 
                                    
Body Width
1.410 inches maximum
 - 
                                    
Overall Height
3.230 inches nominal
 - 
                                    
Functional Terminal Type And Quantity
3 turret output 2nd function
 - 
                                    
Discrimination At Specified Frequencies Per Function In Decibels
3.0 minimum 1st band pass and 30.0 maximum 1st band pass
 - 
                                    
Load Impedance Per Function
600.0 ohms 2nd band pass
 - 
                                    
Frequency Band Width Per Function
2.27375 kilohertz 1st band pass and 2.31625 kilohertz 1st band pass
 - 
                                    
Reference Frequency Per Function
2.295 single radio interference pulses per second
 - 
                                    
Source Impedance Rating Per Function
600.0 ohms 2nd band pass
 - 
                                    
Functional Terminal Type And Quantity
1 turret ground 3rd function
 - 
                                    
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 2nd band pass
 - 
                                    
Mounting Facility Type And Quantity
4 threaded hole
 - 
                                    
Body Material
metal
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    