85-1491-06

Circuit Breakers

CIRCUIT BREAKER

85-1491-06

5925-01-108-4264

5925 - Circuit Breakers

Zenith Electronics Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Length

    0.450 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    1.8 amperes ac single location

  • Inclosure Protection Type For Which Designed

    vibration resistant and humidity resistant and corrosion resistant and hermetically sealed

  • Operating Voltage Type And Rating Per Pole In Volts

    125.0 ac single location

  • Mounting Surface To Terminal End Distance

    1.120 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.640 inches nominal

  • Manual Actuator Type And Quantity

    1 push button

  • Test Data Document

    67177-85-1491 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

  • Overall Length

    1.700 inches maximum

  • Circuit Protection Type

    overcurrent single location

  • Body Length

    1.700 inches maximum

  • Boss Height

    0.120 inches nominal

  • Bushing Length

    0.183 inches minimum and 0.193 inches maximum

  • Pole Quantity

    1

  • Case Material

    metal

  • Trip Release Method

    thermal-magnetic single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Overall Width

    0.550 inches maximum

  • Terminal Type And Quantity

    2 quick disconnect, male

  • Body Style

    single pole type

  • Frequency In Hertz

    60.0 single location

  • Body Width

    0.550 inches maximum

  • Trip Release Characteristic

    instantaneous single location

  • Mounting Facility Type And Quantity

    2 clip

  • Fragility Factor

    moderately rugged

  • Trip Release Ambient Temp Rating

    65.0 deg celsius maximum single location

  • Special Handling Feature

    magnetic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...