113000150
Circuit Breakers
CIRCUIT BREAKER
113000150
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Style
8c multipole-multiple actuator type
-
Body Width
3.750 inches maximum
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Length
1.940 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
-
Mounting Surface To Terminal End Distance
2.491 inches maximum
-
Pole Quantity
5
-
Mounting Facility Type And Quantity
10 threaded hole
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
2.0 amperes dc fourth location
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes dc second location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
any acceptable
-
Trip Release Method
magnetic all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
any acceptable
-
Main Contact Tripping Mechanism Type
trip free
-
Actuator Position Designation
at each pole
-
Internal Trip Release Configuration
series trip all locations
-
Nominal Thread Size
0.138 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.200 minimum at 200 pct and 0.950 maximum at 200 pct fifth location
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.600 minimum at 200 pct and 4.000 maximum at 200 pct first location
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.600 minimum at 200 pct and 4.000 maximum at 200 pct second location
-
Thread Series Designator
unc
-
Terminal Type And Quantity
10 threaded stud
-
Body Length
2.500 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.060 inches nominal
-
Boss Height
0.150 inches nominal
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes dc first location
-
Maximum Continuous Load Current Rating Per Pole
3.0 amperes dc third location
-
Maximum Continuous Load Current Rating Per Pole
4.0 amperes dc fifth location
-
Operating Voltage Type And Rating Per Pole In Volts
65.0 dc all locations
-
Circuit Protection Type
overcurrent all locations
-
Trip Release Characteristic
time delay all locations
-
Reset Method
manual
-
Manual Actuator Type And Quantity
5 toggle
-
Actuator Function
trip-reset
-
External Actuator Linkage Arrangement
one and two linked and three, four, and five linked
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.200 minimum at 200 pct and 0.950 maximum at 200 pct fourth location
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.200 minimum at 200 pct and 0.950 maximum at 200 pct third location
Related Parts by Category
Related Parts by Manufacturer


AS6081 Methods