PFA-32040-GN
Circuit Breakers
CIRCUIT BREAKER
PFA-32040-GN
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Body Style
1d rectangular dimensional envelope
 - 
                                    
Overall Length
13.000 inches nominal
 - 
                                    
Unthreaded Mounting Hole Diameter
0.164 inches nominal
 - 
                                    
Pole Quantity
3
 - 
                                    
Mounting Facility Type And Quantity
4 unthreaded hole
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
10000.0 ac all locations
 - 
                                    
Trip Release Method
thermal-magnetic all locations
 - 
                                    
Trip Release Characteristic
time delay all locations
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Actuator Position Designation
at pole two
 - 
                                    
Trip Release Ambient Temp Rating
40.0 deg celsius nominal all locations
 - 
                                    
Frequency In Hertz
60.0 all locations
 - 
                                    
Terminal Type And Quantity
6 compression
 - 
                                    
Overall Height
6.620 inches nominal
 - 
                                    
Overall Width
8.250 inches nominal
 - 
                                    
Case Material
plastic
 - 
                                    
Iii Storage Type
general purpose warehouse
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
40.0 amperes ac all locations
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
208.0 ac all locations
 - 
                                    
Circuit Protection Type
overcurrent all locations
 - 
                                    
Reset Method
manual
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
100.000 maximum at 200 pct all locations
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
30.000 minimum at 200 pct and
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    