RF08494-2
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
RF08494-2
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Operating Current Rating Per Function In Amps
2.5 2nd radio interference
 - 
                                    
Nominal Thread Size
0.250 inches
 - 
                                    
Load Impedance Per Function
50.0 ohms 1st radio interference
 - 
                                    
Operating Voltage Rating And Type Per Function
115.0 volts ac 4th radio interference 4th function
 - 
                                    
Principal Circuitry Type Per Function
inductance-capacitance 5th radio interference
 - 
                                    
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
 - 
                                    
Power Line Frequency Rating Per Function In Hertz
400.0 1st radio interference
 - 
                                    
Operating Current Rating Per Function In Amps
2.5 3rd radio interference
 - 
                                    
Operating Current Rating Per Function In Amps
1.7 4th radio interference
 - 
                                    
Maximum Temp Rise
25.0 deg celsius
 - 
                                    
Inclosure Type
encased
 - 
                                    
Operating Current Rating Per Function In Amps
1.7 5th radio interference
 - 
                                    
Power Line Frequency Rating Per Function In Hertz
400.0 6th radio interference
 - 
                                    
Body Length
6.500 inches nominal
 - 
                                    
Vibration Resistance Range In Hertz
+4.0/+33.0
 - 
                                    
Load Impedance Per Function
50.0 ohms 2nd radio interference
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
5.875 inches nominal
 - 
                                    
Operating Current Rating Per Function In Amps
1.7 6th radio interference
 - 
                                    
Power Line Frequency Rating Per Function In Hertz
400.0 2nd radio interference
 - 
                                    
Principal Circuitry Type Per Function
inductance-capacitance 6th radio interference
 - 
                                    
Power Line Frequency Rating Per Function In Hertz
400.0 3rd radio interference
 - 
                                    
Operating Voltage Rating And Type Per Function
115.0 volts ac 6th radio interference 6th function
 - 
                                    
Source Impedance Rating Per Function
50.0 ohms 4th radio interference
 - 
                                    
Power Line Frequency Rating Per Function In Hertz
400.0 4th radio interference
 - 
                                    
Body Height
8.000 inches nominal
 - 
                                    
Power Line Frequency Rating Per Function In Hertz
400.0 5th radio interference
 - 
                                    
Special Features
13 functions
 - 
                                    
Body Surface Treatment
tin
 - 
                                    
Operating Voltage Rating And Type Per Function
115.0 volts ac 1st radio interference 1st function
 - 
                                    
Body Material
metal
 - 
                                    
Source Impedance Rating Per Function
50.0 ohms 5th radio interference
 - 
                                    
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
 - 
                                    
Style Designator
rectangular terminal/terminals on one surface
 - 
                                    
Overall Height
8.750 inches nominal
 - 
                                    
Load Impedance Per Function
50.0 ohms 3rd radio interference
 - 
                                    
Source Impedance Rating Per Function
50.0 ohms 6th radio interference
 - 
                                    
Body Width
2.000 inches maximum
 - 
                                    
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
 - 
                                    
Operating Voltage Rating And Type Per Function
115.0 volts ac 2nd radio interference 2nd function
 - 
                                    
Load Impedance Per Function
50.0 ohms 4th radio interference
 - 
                                    
Principal Circuitry Type Per Function
inductance-capacitance 3rd radio interference
 - 
                                    
Operating Current Rating Per Function In Amps
2.5 1st radio interference
 - 
                                    
Operating Voltage Rating And Type Per Function
115.0 volts ac 3rd radio interference 3rd function
 - 
                                    
Mounting Facility Screw Thread Series Designator
unf
 - 
                                    
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
 - 
                                    
Load Impedance Per Function
50.0 ohms 5th radio interference
 - 
                                    
Principal Circuitry Type Per Function
inductance-capacitance 4th radio interference
 - 
                                    
Maximum Dielectric Withstanding Dc Voltage
400.0 volts at sea level
 - 
                                    
Operating Voltage Rating And Type Per Function
115.0 volts ac 5th radio interference 5th function
 - 
                                    
Operating Temp Range
-54.0/+85.0 deg celsius
 - 
                                    
Mounting Facility Type And Quantity
4 captive screws
 - 
                                    
Load Impedance Per Function
50.0 ohms 6th radio interference
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    