HS1215/01/0

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

HS1215/01/0

5915-01-125-5840

5915 - Filters and Networks

Saab Ab Publ - Electronic Defence

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Power Line Frequency Rating Per Function In Hertz

    400.0 3rd radio interference

  • Operating Voltage Rating And Type Per Function

    250.0 volts ac 6th radio interference 6th function

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 4th radio interference

  • Operating Temp Range

    -55.0/+125.0 deg celsius

  • Mounting Slot Width

    0.135 inches maximum

  • Power Line Frequency Rating Per Function In Hertz

    400.0 5th radio interference

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 6th radio interference

  • Vibration Resistance Range In Hertz

    +10.0/+2000.0

  • Operating Current Rating Per Function In Amps

    10.0 3rd radio interference

  • Operating Current Rating Per Function In Amps

    10.0 4th radio interference

  • Body Material

    metal

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Operating Current Rating Per Function In Amps

    10.0 5th radio interference

  • Operating Current Rating Per Function In Amps

    10.0 6th radio interference

  • Operating Voltage Rating And Type Per Function

    250.0 volts ac 4th radio interference 4th function

  • Body Width

    0.710 inches nominal

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

  • Functional Terminal Type And Quantity

    12 tab, solder lug input 1st function

  • Style Designator

    rectangular terminal/terminals on opposite surfaces

  • ~1

    data on certain environmental and performanc

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Overall Height

    1.781 inches maximum

  • Load Impedance Per Function

    50.0 ohms 5th radio interference

  • Specification/standard Data

    81349-mil-f-15733/63 government specification

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th radio interference

  • Operating Voltage Rating And Type Per Function

    250.0 volts ac 2nd radio interference 2nd function

  • Special Features

    12 functions; item 1.202 in. w o/a

  • Overall Length

    1.452 inches maximum

  • Load Impedance Per Function

    50.0 ohms 6th radio interference

  • Operating Voltage Rating And Type Per Function

    250.0 volts ac 5th radio interference 5th function

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 5th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

  • Unpackaged Unit Weight

    49.500 grams

  • Operating Current Rating Per Function In Amps

    10.0 2nd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 1st radio interference

  • Inclosure Type

    encased

  • Mounting Facility Type And Quantity

    6 slot

  • Body Length

    0.975 inches nominal

  • Power Line Frequency Rating Per Function In Hertz

    400.0 2nd radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 6th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 6th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Maximum Temp Rise

    15.0 deg celsius

  • Body Height

    1.157 inches maximum

  • Distance Between Mounting Surface And Lower End

    0.938 inches maximum

  • Operating Voltage Rating And Type Per Function

    250.0 volts ac 3rd radio interference 3rd function

  • Operating Voltage Rating And Type Per Function

    250.0 volts ac 1st radio interference 1st function

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.000 inches nominal

  • Functional Terminal Type And Quantity

    12 tab, solder lug output 2nd function

  • Load Impedance Per Function

    50.0 ohms 4th radio interference

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.250 inches nominal

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd radio interference

  • Operating Current Rating Per Function In Amps

    10.0 1st radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

  • Test Data Document

    81349-mil-f-15733 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...