260-4021-480
Circuit Breakers
CIRCUIT BREAKER
260-4021-480
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Switch Contact Arrangement
single pole, double throw
-
Switch Current Rating And Type In Amps
2.5 ac and 1.0 dc
-
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc
-
Pole Quantity
1
-
Manual Actuator Type And Quantity
1 toggle
-
Internal Trip Release Configuration
series trip single location
-
Nominal Thread Size
0.138 inches
-
Maximum Continuous Load Current Rating Per Pole
500.0 milliamperes ac single location
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 single location
-
Body Style
single pole type
-
Test Data Document
13499-260-4021 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Body Width
0.755 inches minimum and 0.770 inches maximum
-
Boss Height
0.145 inches minimum and 0.160 inches maximum
-
Frequency In Hertz
60.0 single location
-
Thread Pitch Diameters
+0.1177/+0.1214 inches
-
Auxiliary Switch Function And Quantity
1 alarm
-
Trip Release Characteristic
instantaneous single location
-
Switch Location And Position Designation
internal at pole one
-
Case Material
plastic
-
Terminal Type And Quantity
2 threaded stud
-
Features Provided
high inrush protection
-
Fragility Factor
moderately rugged
-
Trip Release Method
magnetic single location
-
Switch Terminal Type
tab, solder lug
-
Special Handling Feature
magnetic
-
Mounting Surface To Terminal End Distance
2.900 inches maximum
-
Thread Series Designator
unc
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location
-
Reset Method
manual
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Body Length
2.530 inches maximum
-
Mounting Facility Type And Quantity
2 threaded hole
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.050 inches minimum and 2.070 inches maximum
-
Thread Quantity Per Inch
32
-
Center To Center Distance Between Terminals Parallel To Length
1.950 inches minimum and 1.970 inches maximum
-
Circuit Protection Type
overcurrent single location
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location
-
Inclosure Protection Type For Which Designed
dustproof and sand resistant and explosion proof and humidity resistant and vibrationproof and salt spray proof
Related Parts by Category
Related Parts by Manufacturer


AS6081 Methods