EH2-B020-F2

Circuit Breakers

CIRCUIT BREAKER

EH2-B020-F2

5925-01-136-6498

5925 - Circuit Breakers

Siemens Energy And Automation Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Unpackaged Unit Weight

    0.240 pounds

  • Mounting Surface To Terminal End Distance

    3.999 inches nominal

  • Nominal Thread Size

    0.164 inches

  • Boss Height

    0.218 inches nominal

  • Terminal Type And Quantity

    4 quick disconnect, female

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.593 inches nominal

  • Inclosure Protection Type For Which Designed

    fungus proof

  • Switch Location And Position Designation

    internal at each pole

  • Body Length

    6.000 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.500 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    1.500 inches nominal

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Switch Terminal Type

    wire lead

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac all locations

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Switch Contact Arrangement

    single pole, double throw

  • Body Style

    multipole-single actuator type

  • Center To Center Distance Between Terminals Parallel To Length

    5.125 inches nominal

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Body Width

    3.000 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Switch Voltage Rating And Type In Volts

    120.0 ac

  • Main Contact Tripping Mechanism Type

    trip free

  • Switch Current Rating And Type In Amps

    20.0 ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    15000.0 ac all locations

  • Fragility Factor

    moderately rugged

  • Trip Release Characteristic

    instantaneous all locations

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Auxiliary Switch Function And Quantity

    2 alarm

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...