44-6-S-H-N-SI

Circuit Breakers

CIRCUIT BREAKER

44-6-S-H-N-SI

5925-01-146-1293

5925 - Circuit Breakers

Oakland Industries Ltd

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Actuator Function

    reset

  • Switch Terminal Type

    tab, solder lug

  • Body Style

    rectangular dimensional envelope

  • Trip Release Ambient Temp Rating

    70.0 deg fahrenheit nominal single location

  • Reset Method

    manual

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc single location

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    300.0 amperes dc single location

  • Manual Actuator Type And Quantity

    1 push button

  • Test Data Document

    80063-sm-a-317335 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

  • Switch Current Rating And Type In Amps

    5.0 dc

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Overall Length

    4.090 inches nominal

  • Switch Contact Arrangement

    single pole, double throw

  • Pole Quantity

    1

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 dc single location

  • Internal Trip Release Configuration

    series trip single location

  • Unpackaged Unit Weight

    30.000 ounces

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Switch Voltage Rating And Type In Volts

    28.0 dc

  • Overall Width

    3.940 inches nominal

  • Mounting Facility Type And Quantity

    2 terminal

  • Terminal Type And Quantity

    2 tab w/screw

  • Overall Height

    1.580 inches nominal

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Trip Delay Time In Seconds Per Rated Continuous Current

    100.000 nominal at 250 pct single location

  • Inclosure Protection Type For Which Designed

    fungus resistant and corrosion resistant and humidity resistant

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...