860-224274C-11

Circuit Breakers

CIRCUIT BREAKER

860-224274C-11

5925-01-149-2957

5925 - Circuit Breakers

Snydergeneral Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Mounting Slot Width

    0.164 inches nominal

  • Body Length

    5.844 inches nominal

  • Body Width

    3.096 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    1.032 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.032 inches nominal

  • Fragility Factor

    moderately rugged

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    6 threaded hole and 6 slot

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac .

  • Circuit Protection Type

    overcurrent .

  • Trip Release Method

    magnetic-hydraulic .

  • Trip Release Characteristic

    time delay .

  • Main Contact Tripping Mechanism Type

    trip free

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip .

  • Nominal Thread Size

    0.138 inches

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Frequency In Hertz

    50.0 or 60.0

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    6 screw

  • Body Style

    caaql 8c

  • Center To Center Distance Between Terminals Parallel To Length

    3.546 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Boss Height

    0.218 inches nominal

  • Mounting Surface To Terminal End Distance

    2.609 inches nominal

  • Pole Quantity

    3

  • Special Handling Feature

    magnetic

  • Features Provided

    high inrush protection

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac .

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac .

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    3 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • Trip Delay Time In Seconds Per Rated Continuous Current

    11.000 minimum at 200 pct and 125.000 maximum at 200 pct .

  • Unpackaged Unit Weight

    2.000 pounds

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.