CD4-Z296-2W
Circuit Breakers
CIRCUIT BREAKER
CD4-Z296-2W
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Test Data Document
49956-g166010 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
 - 
                                    
Trip Release Method
magnetic-hydraulic third location
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac fourth location
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.750 inches nominal
 - 
                                    
Mounting Slot Width
0.164 inches nominal
 - 
                                    
Frequency In Hertz
400.0 third location
 - 
                                    
Trip Release Method
magnetic first location
 - 
                                    
Special Features
four terminals on pole one
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
60.0 amperes ac fourth location
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
140.0 fourth location
 - 
                                    
Manual Actuator Type And Quantity
4 toggle
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
4.000 minimum at 200 pct second location and 10.000 maximum at 200 pct second location
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.032 inches nominal
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
60.0 amperes ac second location
 - 
                                    
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
4.000 minimum at 200 pct third location and 10.000 maximum at 200 pct third location
 - 
                                    
Trip Release Characteristic
instantaneous first location
 - 
                                    
Trip Release Characteristic
time delay fourth location
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
3.546 inches nominal
 - 
                                    
Nominal Thread Size
0.138 inches
 - 
                                    
Trip Release Characteristic
time delay second location
 - 
                                    
Frequency In Hertz
400.0 second location
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Arc Quenching Method
magnetic blowout
 - 
                                    
Trip Release Characteristic
time delay third location
 - 
                                    
Mounting Facility Type And Quantity
8 threaded hole and 8 slot
 - 
                                    
Trip Release Method
magnetic-hydraulic fourth location
 - 
                                    
Boss Height
0.218 inches nominal
 - 
                                    
Trip Release Method
magnetic-hydraulic second location
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
4.000 minimum at 200 pct fourth location and 10.000 maximum at 200 pct fourth location
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
140.0 second location
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac third location
 - 
                                    
Case Material
plastic
 - 
                                    
Pole Quantity
4
 - 
                                    
Body Length
5.844 inches nominal
 - 
                                    
Fragility Factor
moderately rugged
 - 
                                    
Special Handling Feature
magnetic
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
140.0 third location
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac third location
 - 
                                    
Terminal Type And Quantity
10 threaded stud
 - 
                                    
Thread Series Designator
unc
 - 
                                    
Actuator Position Designation
at each pole
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
107.0 dc first location
 - 
                                    
Reset Method
manual
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
60.0 amperes ac third location
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Body Width
3.096 inches nominal
 - 
                                    
Frequency In Hertz
400.0 fourth location
 - 
                                    
Internal Trip Release Configuration
series trip all locations
 - 
                                    
Mounting Surface To Terminal End Distance
2.609 inches nominal
 - 
                                    
Circuit Protection Type
overcurrent fourth location
 - 
                                    
Circuit Protection Type
undervoltage first location
 - 
                                    
Circuit Protection Type
overcurrent second location
 - 
                                    
Thread Quantity Per Inch
32
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac fourth location
 - 
                                    
Center To Center Distance Between Terminals Parallel To Width
1.032 inches nominal
 - 
                                    
Body Style
multipole-multiple actuator type
 - 
                                    
Circuit Protection Type
overcurrent third location
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac second location
 - 
                                    
External Actuator Linkage Arrangement
one, two, three, and four linked
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac second location
 