203-22-1-61-153-5-1-6
Circuit Breakers
CIRCUIT BREAKER
203-22-1-61-153-5-1-6
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Case Material
plastic
 - 
                                    
Mounting Facility Type And Quantity
2 clamp
 - 
                                    
Overall Length
2.000 inches nominal
 - 
                                    
Overall Height
1.320 inches nominal
 - 
                                    
Unpackaged Unit Weight
0.180 ounces
 - 
                                    
Overall Width
1.777 inches nominal
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac all locations
 - 
                                    
Frequency In Hertz
50.0 all locations or 60.0 all locations
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
0.050 minimum at 200 pct all locations and 0.950 maximum at 200 pct all locations
 - 
                                    
Inclosure Protection Type For Which Designed
general purpose
 - 
                                    
Terminal Type And Quantity
2 tab, solder lug
 - 
                                    
Arc Quenching Method
magnetic blowout
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Actuator Position Designation
between pole one and two
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
 - 
                                    
Trip Release Method
magnetic-hydraulic all locations
 - 
                                    
Trip Release Characteristic
instantaneous all locations and time delay all locations
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
 - 
                                    
Internal Trip Release Configuration
series trip all locations
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Reset Method
manual
 - 
                                    
Pole Quantity
2
 - 
                                    
Body Style
rectangular dimensional envelope
 - 
                                    
Circuit Protection Type
overcurrent all locations
 - 
                                    
Special Handling Feature
magnetic
 - 
                                    
Fragility Factor
moderately rugged
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    