1197

Circuit Breakers

CIRCUIT BREAKER

1197

5925-01-162-4001

5925 - Circuit Breakers

Celab Ltd

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Body Length

    1.375 inches nominal

  • Bushing Length

    0.468 inches nominal

  • Pole Quantity

    1

  • Inclosure Protection Type For Which Designed

    vibration resistant

  • Center To Center Distance Between Terminals Parallel To Length

    1.125 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac single location and 15.0 amperes dc single location

  • Body Width

    0.680 inches nominal

  • Terminal Type And Quantity

    2 tab, solder lug

  • Special Features

    hex nut

  • Body Style

    single pole type

  • Trip Release Method

    magnetic-hydraulic single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Frequency In Hertz

    60.0 single location

  • Thread Series Designator

    un

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 32.0 dc single location

  • Case Material

    plastic

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.000 minimum at 200 pct single location and 15.000 maximum at 200 pct single location

  • Special Handling Feature

    magnetic

  • Mounting Surface To Terminal End Distance

    1.540 inches nominal

  • Reset Method

    manual

  • Nominal Thread Size

    0.500 inches

  • Actuator Position Designation

    at pole one

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location and 1000.0 dc single location

  • Storage Type

    general purpose warehouse

  • Criticality Code Justification

    feat

  • Actuator Function

    trip-reset

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...