Technical Characteristics
-
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 minimum at 200 pct fourth location and 100.200 maximum at 200 pct fourth location
-
Body Length
5.844 inches nominal
-
Fragility Factor
moderately rugged
-
Inclosure Protection Type For Which Designed
moisture resistant and humidity resistant and salt water resistant and fungus resistant and shock resistant and vibration resistant
-
Special Handling Feature
magnetic
-
Circuit Protection Type
overcurrent all locations
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac third location
-
Terminal Type And Quantity
10 threaded stud
-
Thread Series Designator
unc
-
Maximum Continuous Load Current Rating Per Pole
90.0 amperes ac all locations
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Body Width
4.128 inches nominal
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Mounting Surface To Terminal End Distance
2.609 inches nominal
-
Trip Release Characteristic
time delay third location
-
Mounting Facility Type And Quantity
8 threaded hole and 8 slot
-
Boss Height
0.218 inches nominal
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations
-
Frequency In Hertz
50.0 all locations or 60.0 all locations
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac fourth location
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.750 inches nominal
-
Mounting Slot Width
0.164 inches nominal
-
Manual Actuator Type And Quantity
4 toggle
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.032 inches nominal
-
Features Provided
high inrush protection
-
Internal Trip Release Configuration
relay trip first location
-
Case Material
plastic
-
Pole Quantity
4
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac second location
-
Arc Quenching Method
magnetic blowout
-
Main Contact Tripping Mechanism Type
trip free
-
Internal Trip Release Configuration
series trip third location
-
Trip Release Characteristic
time delay second location
-
Nominal Thread Size
0.138 inches
-
Center To Center Distance Between Terminals Parallel To Length
3.546 inches nominal
-
Internal Trip Release Configuration
series trip second location
-
Unpackaged Unit Weight
9.500 ounces
-
Trip Release Characteristic
time delay fourth location
-
Trip Release Characteristic
instantaneous first location
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac first location
-
External Actuator Linkage Arrangement
one, two, three, and four linked
-
Internal Trip Release Configuration
series trip fourth location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Body Style
multipole-multiple actuator type
-
Trip Release Method
magnetic-hydraulic all locations
-
Center To Center Distance Between Terminals Parallel To Width
1.032 inches nominal
-
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 minimum at 200 pct second location and 100.200 maximum at 200 pct second location
-
Thread Quantity Per Inch
32
-
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 minimum at 200 pct third location and 100.200 maximum at 200 pct third location
Related Parts by Category
Related Parts by Manufacturer


AS6081 Methods