MIL-R-6106
Relays and Solenoids
RELAY,ELECTROMAGNETIC
MIL-R-6106
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Test Data Document81349--mil-r-83536/9 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general 
- 
                                    Fragility Factormoderately rugged 
- 
                                    Nominal Operating Current Rating And Type110.0 milliamperes dc single winding 
- 
                                    Main Contact Load Current Rating At Maximum Rated Voltage4.0 amperes ac motor load and 4.0 amperes dc motor load 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Criticality Code Justificationfeat 
- 
                                    Time Delay0.01 seconds maximum fixed operate and release time 
- 
                                    Nonpile-Up Main Contact Arrangement2 pole, double throw, one position momentary 
- 
                                    Overall Height1.310 inches maximum 
- 
                                    Specification/Standard Data96906--83536/9-024m government standard 
- 
                                    Precious Materialgold 
- 
                                    Precious Material And Locationterminal surfaces gold 
- 
                                    Purpose For Which Designedspecific 
- 
                                    Environmental Protectionhermetic 
- 
                                    Mounting Slot Width0.150 inches nominal single mounting facility 
- 
                                    Winding Dc Resistance Rating320.0 ohms nominal single winding 
- 
                                    Arc Quenching Methodair 
- 
                                    ~1type data on certain environmental and perform 
- 
                                    Mounting Facility Type And Quantity2 slotted hole single mounting facility 
- 
                                    Main Contact Load Current Rating At Maximum Rated Voltage10.0 amperes ac resistive load and 10.0 amperes dc resistive load 
- 
                                    Mounting Facility Patternin-line single mounting facility 
- 
                                    Center To Center Distance Between Mounting Facilities Parallel To Length1.446 inches nominal single mounting facility 
- 
                                    Duty Typecontinuous 
- 
                                    Main Contact Load Current Rating At Maximum Rated Voltage8.0 amperes ac inductive load and 8.0 amperes dc inductive load 
- 
                                    Coil Quantity1 
- 
                                    Operating Voltage Rating And Type At Specified Temp28.0 volts dc 25 deg celsius single winding 
- 
                                    Terminal Type And Quantity8 pin all functions 
- 
                                    Overall Width0.525 inches maximum 
- 
                                    Main Contact Maximum Voltage Rating In Volts115.0 ac and 28.0 dc 
- 
                                    Main Contact Load Current Rating At Maximum Rated Voltage2.0 amperes ac lamp load and 2.0 amperes dc lamp load 
- 
                                    Case Materialmetal 
- 
                                    Special Featuresfailure rate level 1.0 percent per 10,000 cycles 
- 
                                    Cubic Measure1.181 cubic inches 
- 
                                    Overall Length1.718 inches maximum 
- 
                                    Winding Quantity1 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    