985611-001

Circuit Breakers

CIRCUIT BREAKER

985611-001

5925-01-180-0079

5925 - Circuit Breakers

Titan Corp The

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    10 tab w/screw

  • Thread Series Designator

    unc

  • Frequency In Hertz

    50.0 or 60.0

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Switch Current Rating And Type In Amps

    10.0 ac and 3.0 dc

  • Switch Terminal Type

    tab, solder lug

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.130 minimum at 200 pct and 1.300 maximum at 200 pct second location

  • Internal Trip Release Configuration

    series trip third location

  • Internal Trip Release Configuration

    series trip second location

  • Internal Trip Release Configuration

    relay trip fourth location

  • External Actuator Linkage Arrangement

    two and three linked

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    2 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Trip Release Characteristic

    time delay third location

  • Trip Release Characteristic

    time delay second location

  • Trip Release Method

    magnetic all locations

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac second location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac first location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Trip Release Characteristic

    time delay first location

  • Trip Release Characteristic

    instantaneous fourth location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc fourth location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac third location

  • Operating Voltage Type And Rating Per Pole In Volts

    65.0 dc fourth location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac third location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac second location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac first location

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes dc fourth location

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac second location

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac first location

  • Mounting Facility Type And Quantity

    8 threaded hole

  • Mounting Surface To Terminal End Distance

    2.032 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Case Material

    plastic

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac third location

  • Thread Quantity Per Inch

    32

  • Storage Type

    general purpose warehouse

  • Pole Quantity

    4

  • Switch Contact Arrangement

    single pole, double throw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.660 inches nominal

  • Body Width

    3.015 inches maximum

  • Body Length

    2.000 inches nominal

  • Bushing Length

    0.130 inches nominal

  • Body Style

    1c multipole-multiple actuator type

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.130 minimum at 200 pct and 1.300 maximum at 200 pct third location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.130 minimum at 200 pct and 1.300 maximum at 200 pct first location

  • Switch Location And Position Designation

    internal at pole one

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip first location

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Actuator Position Designation

    at pole two and at pole three

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...