YC-J2B-015
Relays and Solenoids
RELAY,ELECTROMAGNETIC
YC-J2B-015
Leach International Corporation
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Main Contact Load Current Rating At Maximum Rated Voltage
4.0 amperes ac motor load and 4.0 amperes dc motor load
-
Mounting Slot Width
0.133 inches nominal single mounting facility
-
Mounting Facility Pattern
rectangular single mounting facility
-
Overall Height
0.810 inches maximum
-
Winding Dc Resistance Rating
100.0 ohms nominal single winding
-
Storage Type
general purpose warehouse
-
Time Delay
0.006 seconds maximum fixed operate and release time
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.062 inches minimum single mounting facility and 1.078 inches maximum single mounting facility
-
Environmental Protection
hermetic
-
Winding Quantity
1
-
Operating Voltage Rating And Type At Specified Temp
12.0 volts teardrop, two holes type 4f single winding
-
Mounting Facility Type And Quantity
4 slotted hole single mounting facility
-
Terminal Type And Quantity
11 wire hook all functions
-
Main Contact Load Current Rating At Maximum Rated Voltage
2.0 amperes ac lamp load and 2.0 amperes dc lamp load
-
Main Contact Maximum Voltage Rating In Volts
120.0 ac and 28.0 dc
-
Overall Width
0.940 inches nominal
-
Center To Center Distance Between Mounting Facilities Parallel To Width
0.405 inches nominal single mounting facility
-
Overall Length
1.280 inches maximum
-
Coil Quantity
1
-
Nonpile-Up Main Contact Arrangement
3 pole, double throw, one position momentary
-
Duty Type
continuous
-
Features Provided
coil voltage suppression and polarized
-
Main Contact Load Current Rating At Maximum Rated Voltage
10.0 amperes ac resistive load and 10.0 amperes dc resistive load
Related Parts by Category
Related Parts by Manufacturer
Certified toAS6081 Methods